Special precautions for disposal and other handling: No special requirements are needed for disposal of container, overwrap and oxygen absorber.
Only completely clear solutions from undamaged containers are to be used.
The design of the dual chamber bag permits aseptic mixing of amino acids, glucose and optional fat in the lower chamber. The addition of further electrolytes is possible if required.
Immediately before use the internal peal seam between the two compartments must be opened allowing the respective contents to be aseptically mixed.
Remove the bag from its protective bag and proceed as follows: Open out the bag and lay on a solid surface.
Open the peel seam by using pressure with both hands.
Briefly mix the contents of the bag together.
An additive port is provided for admixing of supplements to Nutriflex Peri/Nutriflex Plus. Only mixtures of known compatibility should be prepared. Information on compatibility of specified mixtures is available from the manufacturer. When admixing other solutions or fat emulsions to Nutriflex Peri/Nutriflex Plus, aseptic precautions must be strictly observed. Fat emulsions can be easily admixed by means of a special transfer set.
After infusion, any remaining solution should never be stored for later use.